Softpaq Solution: SP1087 Filename: CPQCPPRO Title: Pentium Floating Point Instruction Counting Application Version: 1.00 Rev A ______________________________________________________________________ CATEGORY: Software Solution / Miscellaneous EFFECTIVITY DATE: 1-9-95 PRODUCTS AFFECTED: All Compaq Pentium Machines with faulty FPU OPERATING SYSTEM: MS-DOS 5.0 or greater and Windows 3.1 or greater SYSTEM CONFIGURATION: As per OPERATING SYSTEMS, above. SUPERCEDES: None DESCRIPTION: This application/driver is used to monitor the number of faulty floating point instructions executed under Windows. The file CPQCPPRO.EXE is copied to the C:\WINDOWS\CPQWIN subdirectory. CPQCPPRO.386 is copied to the C:\WINDOWS\SYSTEM subdirectory. SYSTEM.INI is modified. HOW TO USE: 1. After downloading the SoftPaq, copy it to an empty directory on your hard drive and change to that directory. If downloaded in zipped format (.ZIP), unzip the file to create an executable: PKUNZIP SP1087 2. From that drive and directory, execute the SoftPaq file to unbind the primary files: SP1087 [ENTER] The following files should be created: INSTALL.EXE WINP5RD.TXT CPQCPPRO.EXE CPQCPPRO.386 SP1087.DOC 3. To install and use the software, refer to SP1087.DOC and WINP5RD.TXT.