DOCUMENT:Q216913 TITLE :BIOS Date Value Does Not Immediately Update on January 1, 2000 PRODUCT :Windows NT PROD/VER:4.0 OPER/SYS:WINDOWS NT KEYWORD :kbbug4.00 kbfix4.00 ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Windows NT Workstation versions 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3, 4.0 SP4, 4.0 SP5 - Microsoft Windows NT Server versions 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3, 4.0 SP4, 4.0 SP5 - Microsoft Windows NT Server, Enterprise Edition versions 4.0, 4.0 SP4, 4.0 SP5 - Microsoft Windows NT Server version 4.0, Terminal Server Edition ------------------------------------------------------------------------------- SYMPTOMS ======== Windows NT 4.0 Service Pack 5 addresses the following problem in Windows NT 4.0: When the Windows NT System Time value rolls over from the year 1999 to 2000, the Century Byte value stored in the real time clock (RTC) is not changed until up to one hour later when the time daemon writes out the date. This issue only affects systems with older BIOSes that do not automatically update the century byte on reboot (contact your hardware manufacturer for BIOS details). This issue may cause unexpected behavior under two conditions: - When your computer is configured using the dual boot option where another operating system may not handle this situation properly. All versions of MS-DOS fall into this category. - Some computer hardware BIOS configurations detect this behavior as an invalid date and present a query for the correct date. This may prevent a computer from restarting without user input. NOTE: This problem only occurs if the computer is restarted during the time lapse when the dates were out of synch. On August 5, 1999, Microsoft released an updated version of BIOS-fix that was originally included with Windows NT 4.0 Service Pack 5. In addition to the above, the latest version of this update corrects the following problems: - If a computer is set to a time zone which does not participate in Daylight Saving Time, refreshing the real time clock for the Year 2000 does not work. - The original update did not replace the multi-processor kernel if it existed. The updated version does. RESOLUTION ========== WINDOWS NT A supported fix that corrects this problem is now available from Microsoft, but it has not been fully regression tested and should be applied only to systems experiencing this specific problem. If you are not severely affected by this specific problem, Microsoft recommends that you wait for the next Windows NT 4.0 service pack that contains this fix. To resolve this problem immediately, contact Microsoft Product Support Services to obtain the fix. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web: http://www.microsoft.com/support/supportnet/overview/overview.asp If you are running Windows NT 4.0 Service Pack 5: This update has been posted to the following Internet location as Biosfixi.exe (x86) and Biosfixa.exe (Alpha): ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/usa/NT40/hotfixes-postSP5/Y2K/BIOS2-fix To determine if a localized version of this software update is available, change "USA" in the URL above to the appropriate localized abbreviation. Click here (ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/readme.txt) for a list of these abbreviations. If you are running Windows NT 4.0 Service Pack 4: This software update has been posted to the following Internet location as Biosfixi.exe (x86) and Biosfixa.exe (Alpha): ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/usa/NT40/ hotfixes-postSP4/Y2K/BIOS2-fix/ To determine if a localized version of this software update is available, change "USA" in the URL above to the appropriate localized abbreviation. Click here (ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/readme.txt) for a list of these abbreviations. For information on obtaining Windows NT 4.0 Service Pack 5, please see the following article in the Microsoft Knowledge Base: Q152734 How to Obtain the Latest Windows NT 4.0 Service Pack TERMINAL SERVER A supported software update that corrects this problem is now available from Microsoft, but it has not been fully regression tested and should be applied only to systems experiencing this specific problem. If you are not severely affected by this specific problem, Microsoft recommends that you wait for the next Windows NT 4.0, Terminal Server Edition service pack that contains this software update. To resolve this problem immediately, contact Microsoft Product Support Services to obtain the software update. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web: http://www.microsoft.com/support/supportnet/overview/overview.asp The English version of this update should have the following file attributes or later: Date Time Size File name Platform ------------------------------------------------------- 06/17/99 06:30p 991,808 Ntkrnlmp.exe x86 06/17/99 06:30p 971,008 Ntoskrnl.exe x86 06/19/99 02:43p 1,461,504 Ntkrnlmp.exe Alpha 06/19/99 02:43p 1,459,712 Ntoskrnl.exe Alpha This software update has been posted to the following Internet location as Biosfixi.exe (x86) and Biosfixa.exe (Alpha): ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/usa/NT40tse/ hotfixes-postSP4/Y2K/BIOS2-fix/ To determine if a localized version of this software update is available, change "USA" in the URL above to the appropriate localized abbreviation. Click here (ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/readme.txt) for a list of these abbreviations. STATUS ====== WINDOWS NT 4.0 Microsoft has confirmed this to be a problem in Windows NT version 4.0. This problem was first corrected in Windows NT version 4.0 Service Pack 5. WINDOWS NT SERVER 4.0, TERMINAL SERVER EDITION Microsoft has confirmed this to be a problem in Windows NT Server 4.0, Terminal Server Edition. MORE INFORMATION ================ How to determine which version of the update you have installed: Original Windows NT 4.0 Post-SP4 Biosfixa.exe 11/23/98 05:01p 1,413,440 ntkrnlmp.exe 11/23/98 05:00p 1,385,152 ntoskrnl.exe Original Windows NT 4.0 Post-SP4 Biosfixi.exe 11/23/98 05:01p 948,160 ntkrnlmp.exe 11/23/98 05:00p 928,192 ntoskrnl.exe New Windows NT 4.0 Post-SP5 Biosfixa.exe 07/27/99 10:10a 1,417,664 ntkrnlmp.exe 07/27/99 10:09a 1,389,248 ntoskrnl.exe New Windows NT 4.0 Post-SP5 Biosfixi.exe 07/27/99 10:11a 951,296 ntkrnlmp.exe 07/27/99 10:10a 931,200 ntoskrnl.exe New Windows NT 4.0 Post-SP4 Biosfixa.exe 07/15/99 03:40p 1,413,504 ntkrnlmp.exe 07/15/99 03:40p 1,385,152 ntoskrnl.exe New Windows NT 4.0 Post-SP4 Biosfixa.exe 07/15/99 03:36p 949,824 ntkrnlmp.exe 07/15/99 03:36p 929,792 ntoskrnl.exe Original TSE Post-SP4 Biosfixa.exe 06/19/99 02:43p 1,461,504 ntkrnlmp.exe 06/19/99 02:43p 1,459,712 ntoskrnl.exe Original TSE Post-SP4 Biosfixi.exe 06/17/99 06:30p 991,808 ntkrnlmp.exe 06/17/99 06:30p 971,008 ntoskrnl.exe New TSE Post-SP4 Biosfixa.exe 08/04/99 11:47a 1,461,568 ntkrnlmp.exe 08/04/99 11:46a 1,432,320 ntoskrnl.exe New TSE Post-SP4 Biosfixa.exe 08/03/99 01:13p 992,448 ntkrnlmp.exe 08/03/99 01:12p 971,648 ntoskrnl.exe Additional query words: y2k tse wts ============================================================================ THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.